Search…
Upgrade LS1 to LS1R X
Once you have your LS1-x kit, please read carefully and follow the instructions step by step to replace the battery and housing.
LS1 Upgrade to LS1-x 07-22.pdf
676KB
PDF
When you’re all done contact your supplier or email [email protected] and let us know. We will reset your battery level and record that you have completed the upgrade.
  1. 1.
    Unscrew the lock ring anti-clockwise and remove.
2. Carefully pull the radar and connected circuit board from the case
3. Unplug the battery cable from the board. Do not disconnect the board from the sensor.
4. Cut the zip tie with a pair of scissors and remove. Please make sure the ends of the scissors do not touch the board.
5. Hold the board firmly on the edges and be careful not to twist the circuit board.
Slowly detach the old battery from the double-sided tape and then remove the double sided tape from the board.
6. Plug the new battery cable into the circuit board.
7. Get your new case. If you have multiple sensors, check that the serial number on the new case matches the sensor you are upgrading. Place the battery into the cradle in the new case. The battery wires should be on the left side of the cradle.
8. Slide the circuit board and radar into the new case over the battery. Keep the wires to the left and be careful not to pinch the battery wires between the circuit board and the new case.
Push the case and radar together to compress the o-ring.
9. Screw the lock ring back on and you’re good to go! Make sure the lock ring is tightly screwed on to prevent water and dust from damaging your sensor.
Copy link